黑料福利网

banner

Products

Home>Products> SATA PPE > Respiratory Protection

SATA FH0511 Reusable TPE Half Facepiece Respirator - Single Cartridge For Gas/Vapor/Dust Protection

FH0511 TPE Gas Mask Half Facepiece Body (Single Cartridge)

SATA FH0511 Reusable TPE Half Facepiece Respirator - Single Cartridge For Gas/Vapor/Dust Protection

Liteng Machinery is professional for its high-end products of sata fh0511 reusable tpe half facepiece respirator - single cartridge for gas/vapor/dust protection, which is high in quality, reliability, strong in durability, and reliable in performance. We are one of the professional Chinese sata fh0511 reusable tpe half facepiece respirator - single cartridge for gas/vapor/dust protection factory. Welcome to get new loader made in China from us.

 

ScreenShot2026-02-27101037868

202409291457369358

202409291457371858

202409291457372806

202409291457374046

202409291457375139

202409291457376409

202409291457377483

1

2

product-750-1000

Products Description

FH0511 TPE Gas Mask Half Facepiece Body (Single Cartridge)

Brand: SATA | Product: TPE Gas Mask Half Facepiece Body | Standard: GB2890-2022
FH0511 is a TPE material half facepiece body with single cartridge design, requiring matching filter cartridges. The TPE material is lightweight and cost-effective, suitable for environments with harmful gases, vapors, or mixed dust and gas hazards.

Accessories Matching

Image

Part No.

Product Name

Protection Target

0602

 

FH0602

A1 Filter Cartridge (Single, Organic Vapors)

Organic Vapors
Ex: Benzene & homologues, gasoline, acetone, carbon disulfide, ether, carbon tetrachloride, chloroform, cyclohexane, nitromethane, ethanol, etc.

0603

FH0603

K1 Filter Cartridge (Single, Ammonia & Organic Ammonia Derivatives)

Ammonia & Organic Ammonia Derivatives
Ex: Ammonia, methylamine, etc.

0604

FH0604

E1 Filter Cartridge (Single, Acid Gases)

Acid Gases
Ex: Sulfur dioxide, chlorine, hydrogen chloride, hydrogen bromide, etc.

0605

FH0605

A1E1 Filter Cartridge (Single, Acid Gases & Organic Vapors)

Organic & Acid Gases
Organic vapors: Benzene & homologues, gasoline, acetone, ether, cyclohexane, nitromethane, ethanol, etc.
Acid gases: Chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, hydrogen sulfide, etc.

0607

FH0607

Pre-filter (For use with single cartridge filter boxes)

Particulate matter

0618

FH0618

Filter Cover (For single cartridge filter boxes)

For securing FH0607 pre-filter to SATA FH06 series filter cartridges

0606

FH0606

Filter Holder (For FH0511, FH0601 half masks)

Connects with FH0601, FH0511 half masks; compatible with FH0609A series filters

0609

FH0609

KN95 Filter (For use with FH0606 holder)

Particulate matter

0609L

FH0609L

KN95 Filter - Long Life Type (For use with FH0606 holder)

Long-life particulate matter

0609A

FH0609A

KN95 Particulate Filter (For use with FH0606 holder)

Particulate matter

0609C

FH0609C

KN95 Activated Carbon Particulate Filter (With activated carbon, for use with FH0606 holder)

Odor removal, particulate filtration

 

 

Key Features

01

Single Cartridge Design

Simple structure, lightweight, wide field of view, suitable for moderate hazard environments.

02

TPE Material

TPE material is lightweight and soft with good sealing, more cost-effective than silicone.

03

Reusable

Facepiece body is reusable, only filter cartridges need replacement, economical and eco-friendly.

 

Applications

  • Organic vapor environments: Painting, cleaning, chemical processing.

  • Acid gas environments: Electroplating, pickling.

  • Dust and gas mixed environments: Requiring both particulate and gas protection.

Specifications
Parameter FH0511
Standard GB2890-2022
Product Type Half Facepiece Body
Material TPE
Cartridge Interface Single Interface
Frequently Asked Questions

Q: How to match facepiece body with filter cartridges?

A: FH0511 is a single-cartridge half facepiece body. Select appropriate filter cartridge types (Type A, Type B, etc.) based on the hazardous environment.

Q: How to choose between TPE and silicone materials?

A: TPE is lightweight and cost-effective for general use. Silicone is softer, more comfortable, and more aging-resistant for extended wear or high-comfort requirements.

Q: How often should filter cartridges be replaced?

A: Replace immediately when odors are detected, dizziness occurs, or breathing resistance increases significantly. Replacement interval depends on environmental concentration and usage time.

Q: Can this protect against all harmful gases?

A: No. Filter cartridges have specific protection targets. Type A cartridges are for organic vapors, Type B for acid gases, etc. Choose appropriate cartridge types based on specific hazards.

Q: How to clean and maintain the facepiece?

A: Clean with mild detergent and water, air dry naturally. Avoid strong acids, alkalis, or organic solvents. Store in a cool, dry place.

Hot Tags: sata fh0511 reusable tpe half facepiece respirator - single cartridge for gas/vapor/dust protection, China, Chinese, factory, new